EMS is an energy management system
- The Energy Management System (EMS – Energy Management System) is a complex of hardware and software that allows you to optimize the amount of energy consumption, forecast and control the processes of using the required amount of energy resources.
- The MADEK company proposes to implement an energy management system based on devices manufactured by the SATEC plant (Israel).
MADEK
SATEC
NVP MADEK is an official partner of SATEC on the territory of Ukraine
Ключові фактори створення системи енергоменеджемента (EMS):
- The difference between tariff plans for electricity supply (can reach up to 20%)
- Choosing the most economical source of energy supply
- Subscription fee for connection (infrastructure fee)
- Increasing energy efficiency and instant analysis of the result of implementing energy-efficient solutions
- Control of the quality and quantity of electricity
- Energy balance and control of energy consumption
Stages of implementation of the EMS system:
Enterprise audit and energy management system design
Installation of equipment
Collection and analysis of data on the consumption of energy flows
Power quality monitoring
Typical places for installing SATEC devices
- Main entries (delimitation points of balance sheet ownership)
- The main indicators of power consumers
- Variable seasonal / daily consumers
- Consumers whose reliable operation depends most on the quality of electricity
- Control and accounting of energy consumption of tenants’ resources
- Common areas & nbsp; (It is possible to use a “virtual counter”)
EMS system architecture (example)

Basic measuring devices
Multi-channel measuring device SATEC BFM136/2
Features:
- Modular or block design
- 18, 24, 30, 36, 42 or 54 measuring channels
- Modules of discrete inputs, relays and analog outputs – 18DI; 4DI/4RO; 4AI
- Color LCD display (optional)
- 256 MB of independent memory
- Protocols: Modbus, МЕК60870-5-101/104, DNP 3.0
- Control of the quality of electrical energy
- ETH, RS-485, USB in the base
- Multi-tariff accounting system



Electricity measurement and analysis
Special high-precision transformers
Characteristics:
- The distance to the device is up to 200 meters
- Ability to work with disconnected secondary circuits
- Nominal current – 10A – 3000A
- The measured current is 0.05A – 3000A
The MADEK company offers for implementation an energy management system based on devices manufactured by the SATEC plant (Israel)
PM175 – Power quality analyzer
Power quality control:
- Power quality control in accordance with GOST 13109-97, GOST 51317, EN50160, GOST R 32144-2013
- Oscillography of currents and voltages
- Direction of harmonics (distortion source detection)
- Flicker dose measurement according to MEK 61000-4-15
Data registration:
- 12 logs for writing data to non-volatile memory
Programmable logic controller:
- 16 programmable settings
- 2 discrete inputs / 2 programmable relays / 2 analog outputs
Communication:
- 2 independent communication ports (RS232/RS422, RS485, Ethernet, Profibus DP)
PM130 PLUS - Multifunctional measuring device (MIP) - telemechanics, ASDUE, ASTUE
- Measurement of voltages, currents, frequency, powers, cos f, asymmetry of currents and voltages, neutral current and their averaged values.
- Measurement of current values (True RMS)
- Current measurement range 1-200% Inom
- Accuracy class 0.5S
- Event log, a log for recording data
- Assigning timestamps
- Basic control of KE: measurement of KIS by current and voltage, individual harmonics up to the 40th
Specialized software complex
Features:
- Online monitoring of all network parameters, data archiving
- A complete set of tools for creating a billing system
- Consumption rationing
- Registration of emergency events
- Import / Export of data
- Instant notification based on a customizable algorithm
System capabilities
At what tariff will the total payment for electricity be cheaper?
Instant calculation. Comparison of payment programs. Visual interface.
Heat map
Ability to visually monitor the minimum and maximum consumption of electricity. Time and day of maximum consumption.
Detailed schedule of electricity consumption by area
Comparison of consumption over time
Virtual appliances: sum up consumption from several inputs in real time. In this way, we can control the total consumption of the object even if it receives power from different sources.
An example of savings

Monitoring of ventilation
From the schedule, we can see that the ventilation operation has a constant schedule that repeats every day. On 22.09, the ventilation was switched to economic mode. Remove night consumption. The peak consumption is reduced, saving about 4 kWh * 8760 = 70,000 UAH / year.

On the night from September 22 to September 23, this lighting was turned off from 11:50 p.m. to 8 a.m. On other days, lighting works 24/7. Potential savings = 5 kW * 8 hours = 40 kWh / day = 29,000 UAH / year.
EMS - energy management system allows:
- Reduce electricity costs by 10-15%
- Identify “bottlenecks” and problem areas in the enterprise’s power grid
- Provide highly accurate accounting of the quantity and quality of electricity
- Discretion of electricity accounting for each site or stand of the data center
- Ensure the flexibility and compactness of the solution (1 BFM device – 54 meters / measuring points)
- Integrate with other BMS, SCADA, ERP, CRM, accounting systems
- The payback period is up to 10-12 months after the start of work
- Control from any computer or mobile device
- Quick analysis with a minimum of information about the operating mode and loads
- Visual display of data
Solutions based on Satec devices and energy management systems (EMS) are already being used in Ukraine:
- Tobacco company “V.A.T. – Pryluky” – 230 accounting points
- Kremenchug city milk factory – 59 accounting points
- NEC “Ukrenergo”
- MTS (Vodafone)
- PrivatBank – 86 accounting points
- Novus Ukraine shopping center network
- Hotel complex “GOODZONE”
- Art Mall shopping center
- NewTelco data center (Kyiv) – 72 accounting points
- Data Center TOP NET – 36 accounting points
- Data Center Volia-cabel
- EPAM Data Center
- Data center Best (Kyiv) – 36 accounting points
- NBU, Chernivtsi